| Sign In | Join Free | My entremaqueros.com | 
 | 
Brand Name : MTL
Model Number : 5531
Place of Origin : China
MOQ : 1
Price : Negotiable
Payment Terms : T/T
Supply Ability : 100+pc+on stock
Delivery Time : on request
Packaging Details : carton
Manufacture : MTL
Model Type : Vibration Transducer Interface
Part Number : 5531
Sensor type : 2- or 3-wire vibration transducer
Signal range : Minimum –20V, maximum –0.5V
Supply voltage : 20 to 35V dc
Leading time : On request
Shipping weight : 2 Kg
Manufacturer : MTL Instruments
 Product No. : MTL5531
 Product Type : Vibration Transducer Interface
 Number of channels : One
 Sensor type : 2- or 3-wire vibration transducer
 Location of signal source : Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location
 Hazardous-area input : Input impedance (terminals 2 & 3): 10k?
 Transducer supply current, 2-wire : 3.3mA (nom.) for 2-wire sensors, user selectable by switch
 Signal range : Minimum –20V, maximum –0.5V
 DC transfer accuracy at 20°C : <±50mV
 LED indicator : Green = power indication
 Supply voltage : 20 to 35V dc
 Maximum current consumption (10mA transducer load) : 65mA at 24V
 Maximum power dissipation within unit : 1.33W
 Weight : 0.11 Kg
MTL 5531 repeats a signal from a vibration sensor in a hazardous area, providing an output for a monitoring system in the safe
area. The interface is compatible with 3-wire eddy-current probes and accelerometers or 2-wire current sensors; the selection is
made by a switch on the side of the module.
| Sensor type | 2- or 3-wire vibration transducer | 
| Location of signal source | Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location | 
| Hazardous-area input | Input impedance (terminals 2 & 3): 10kΩ | 
| Transducer supply current, 2-wire | 3.3mA (nom.) for 2-wire sensors, user selectable by switch | 
| Signal range | Minimum –20V, maximum –0.5V | 
| DC transfer accuracy at 20°C | <±50mV | 
| AC transfer accuracy at 20°C | 0Hz to 1kHz: ±1% 1kHz to 10kHz: –5% to +1% 10kHz to 20kHz: –10% to +1% | 
| Temperature coefficient | ±50ppm/°C (10 to 65°C) ±100ppm/°C (–20 to 10°C) | 
| Voltage bandwidth | –3dB at 47kHz (typical) | 
| Phase response | <14µs, equivalent to: –1° at 200Hz –3° at 600Hz –5° at 1kHz –50° at 10kHz –100° at 20kHz | 
| Safe-area output impedance | <20Ω | 
| Supply voltage | 20 to 35V dc | 
| Safety description | Terminals 3 to 1 Uo=26.6V Io=94mA Po=0.66W Um = 253V rms or dc Terminals 3 to 2 Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW | 
| Note | Refer to the Instruction Manual for recommendations on mounting of these modules. Due to the high power dissipation the maximum ambient temperature for these modules when mounted in horizontal orientation is: • close packed 45°C • minimum of 10mm spacing 55°C | 




|   | 
| 5531 Vibration Transducer Interface MTL Instruments 20 To 35VDc Images | 
 MTL5018 MTL Instruments Proximity Detector Interface
                                                                                    
                        
                        
                        
                                                            MTL5018 MTL Instruments Proximity Detector Interface
                                                    
                        
                     Blue MTL Safety Barrier MTL4573 With Iron In Stock Original Package
                                                                                    
                        
                        
                        
                                                            Blue MTL Safety Barrier MTL4573 With Iron In Stock Original Package
                                                    
                        
                     MTL5514 Switch / Proximity Detector Interface Normal Phase
                                                                                    
                        
                        
                        
                                                            MTL5514 Switch / Proximity Detector Interface Normal Phase
                                                    
                        
                     MTL5525 MTL Safety Barrier Low Current Loop Powered Solenoid Alam Driver
                                                                                        
                                                        
                        
                        
                        
                                                            MTL5525 MTL Safety Barrier Low Current Loop Powered Solenoid Alam Driver
                                                    
                        
                     Pulse Isolator MTL5532 MTL Instrument From Switch Proximity Detector
                                                                                        
                                                        
                        
                        
                        
                                                            Pulse Isolator MTL5532 MTL Instrument From Switch Proximity Detector
                                                    
                        
                     HART MTL5546 MTL Safety Barrier , 20mA Mtl Barriers 5500 Series
                                                                                        
                                                        
                        
                        
                        
                                                            HART MTL5546 MTL Safety Barrier , 20mA Mtl Barriers 5500 Series
                                                    
                        
                     MTL5549Y Isolating Driver Two Channel For 4 - 20mA HART Valve Positioner
                                                                                        
                                                        
                        
                        
                        
                                                            MTL5549Y Isolating Driver Two Channel For 4 - 20mA HART Valve Positioner
                                                    
                        
                     TP48-4-N-NDI MTL Surge Protection ATEX approved
                                                                                    
                        
                        
                        
                                                            TP48-4-N-NDI MTL Surge Protection ATEX approved
                                                    
                        
                     50 mA MTL7760AC MTL Safety Barrier Analogue Inputs Low Level Barrier
                                                                                        
                                                        
                        
                        
                        
                                                            50 mA MTL7760AC MTL Safety Barrier Analogue Inputs Low Level Barrier
                                                    
                        
                     20mA MTL7796 MTL Intrinsically Safe Barriers , 2 Wire MTL Zener Barrier
                                                                                    
                        
                        
                        
                                                            20mA MTL7796 MTL Intrinsically Safe Barriers , 2 Wire MTL Zener Barrier